The pull-in time of 400a/48v DC contactor ZJ400AB is ≤30 (ms), the release time is ≤50 (ms), the contact material is AgCuO (10)/Cu, the protection level is IP50, longer service life, stable structure, high performance excellent.

Ordering Notice

For example: ZJ400AB/12V
The DC contactor of main contact is one  NC, rated voltage not more than DC 80V, current 400A, coil

Basic Technical Parameters (at normal conditions)
Electric Parameters
Contact type One pair of bridge type moving
open (NO) contacts
Instantaneous maxi (closing) current 7Ie,≤1s
Rated voltage of contacts (DC) ≤80V Insulation resistance(MΩ) ≥100
Rated current of contacts (A) 400 Dielectric withstand voltage 1500V,p.f. 1min, no breakdown
Voltage drop on contacts(mV) ≤80 (at 100A) Electric cycles (104) ≥2
Coil voltage specification(DC) 12V, 24V, 48V, 72V etc Mechanical cycles (104) ≥30
DC power consumption of coil (W) See coil parameter table Temperature rise on outgoing terminal ≤65
Pickup voltage(DC) ≤75%Us Temperature rise of coil(K) ≤85
Release voltage(DC) ≥5%Us;≤40%Us Insulation grade of enameled wire Class B (130°C)
Pickup time(ms) ≤30 Material of contact AgCuO(10)/Cu
Release time(ms) ≤50 Working duty Continuous operating duty
Mechanical/Ambient Conditions
Torque of outgoing 
terminal  on contact M10(N.m)
≯20.5N appropriate Protection grade IP50
Torque of outgoing 
terminal  on coil M4(N.m)
≯1.2N appropriate Mounting methods Freely
Working temperature (-25~+55)°C Vibration Sine shock: 2.5g, (5~50) Hz
Mounting altitude ≤2Km Impact 50g,11ms(Half sine)
Conversion Table for Coil Specification(20°C)
Voltage(V) Coil resistance(1±10%)Ω Voltage(V) Coil resistance(1±10%)Ω
Start up Keep Start up Keep
12 3.3 24 60 24.4 661.5
24 5.68 81.8 72 33 1033
48 18.2 362 80 49.2 1066.7

Outline and Mounting Picture

Mini Circuit Breaker
Related Products
ZJ200DB DC Contactor
ZJ200DB DC Contactor

The products are mainly used to control switching on/off of power supp

ZJ200D DC Contactor
ZJ200D DC Contactor

The products are mainly used to control switching on/off of power supp

ZJ400A DC Contactor
ZJ400A DC Contactor

The products are mainly used to control switching on/off of power supp

ZJ400D DC Contactor
ZJ400D DC Contactor

The products are mainly used to control switching on/off of power supp

GET A QUOTE

+86 13738766933

king@kingnan.com

GET IN TOUCH NOW
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All